Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Vasc Bras ; 20: e20200191, 2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34188669

RESUMO

BACKGROUND: The contrast power injector (CPI) is the gold standard method for injecting contrast with the pressure and flow needed to generate a satisfactory images during endovascular procedures, but it is an expensive tool, narrowing its wide-scale applications. One alternative is the manual injection (MI) method, but this does not generate the pressure required for adequate visualization of anatomy. It is therefore imperative to create an alternative low-cost method that is capable of producing high quality images. OBJECTIVES: To compare the injection parameters of a new mechanical device (Hand-Crank) created in a university hospital with the MI method and with the contrast power injector's ideal values. METHODS: A circulation phantom was constructed to simulate the pressure in the aorto-iliac territory and the injection parameters of the two methods were compared in a laboratory setting. Student's t test and the Mann-Whitney test were used for statistical analysis. Three vascular surgery residents (the authors) performed the injections (each performed 9 tests using conventional manual injection and 9 tests using the Hand-Crank, totaling 54 injections). RESULTS: There were statistical differences between the two methods (p<0.05) in total volume injected until maximum pressure was attained, pressure variation, maximum pressure, total injection time, and time to reach the maximum pressure. CONCLUSIONS: The Hand-Crank can achieve higher maximum pressure, higher average flow, and lower injection time than the manual method. It is a simple, low-cost, and effective tool for enhancing injection parameters in an experimental setup. It could help to produce higher quality images in a clinical scenario.


CONTEXTO: A bomba injetora é o método padrão-ouro para a injeção de contraste em aortografias. Entretanto, é uma ferramenta de alto custo, o que limita o seu uso. A injeção manual surge como alternativa, mas a pressão gerada com esse método é baixa, e, por isso, a qualidade das imagens não é usualmente satisfatória. Assim, a criação de um método de baixo custo capaz de gerar imagens de qualidade é imperativo. OBJETIVOS: Comparar os parâmetros de injeção de um novo dispositivo mecânico (manivela articulada) criado em um hospital universitário com os parâmetros da injeção manual e com os valores ideais da bomba injetora. MÉTODOS: Um simulador do território aórtico foi construído, e parâmetros de injeção entre os diferentes métodos em um cenário laboratorial controlado foram analisados. O teste t de Student e o teste de Mann-Whitney foram usados para análise estatística. Três residentes de Cirurgia Vascular realizaram os testes (nove usando o novo dispositivo, e nove usando a injeção manual, totalizando 54 injeções). RESULTADOS: Houve diferença estatisticamente significativa (p < 0,05) entre os dois métodos, considerando os parâmetros: variação de pressão, pressão máxima, tempo de injeção, tempo até a pressão máxima e volume até a pressão máxima. CONCLUSÕES: A manivela articulada atingiu níveis superiores de pressão e de velocidade de injeção, com menor tempo de injeção do que a injeção manual. É um dispositivo simples, de baixo custo e com resultados comparáveis à bomba injetora, o que sugere seu uso potencial na geração de imagens satisfatórias em aortografias.

2.
J. vasc. bras ; 20: e20200191, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1279371

RESUMO

Abstract Background The contrast power injector (CPI) is the gold standard method for injecting contrast with the pressure and flow needed to generate a satisfactory images during endovascular procedures, but it is an expensive tool, narrowing its wide-scale applications. One alternative is the manual injection (MI) method, but this does not generate the pressure required for adequate visualization of anatomy. It is therefore imperative to create an alternative low-cost method that is capable of producing high quality images. Objectives To compare the injection parameters of a new mechanical device (Hand-Crank) created in a university hospital with the MI method and with the contrast power injector's ideal values. Methods A circulation phantom was constructed to simulate the pressure in the aorto-iliac territory and the injection parameters of the two methods were compared in a laboratory setting. Student's t test and the Mann-Whitney test were used for statistical analysis. Three vascular surgery residents (the authors) performed the injections (each performed 9 tests using conventional manual injection and 9 tests using the Hand-Crank, totaling 54 injections). Results There were statistical differences between the two methods (p<0.05) in total volume injected until maximum pressure was attained, pressure variation, maximum pressure, total injection time, and time to reach the maximum pressure. Conclusions The Hand-Crank can achieve higher maximum pressure, higher average flow, and lower injection time than the manual method. It is a simple, low-cost, and effective tool for enhancing injection parameters in an experimental setup. It could help to produce higher quality images in a clinical scenario.


Resumo Contexto A bomba injetora é o método padrão-ouro para a injeção de contraste em aortografias. Entretanto, é uma ferramenta de alto custo, o que limita o seu uso. A injeção manual surge como alternativa, mas a pressão gerada com esse método é baixa, e, por isso, a qualidade das imagens não é usualmente satisfatória. Assim, a criação de um método de baixo custo capaz de gerar imagens de qualidade é imperativo. Objetivos Comparar os parâmetros de injeção de um novo dispositivo mecânico (manivela articulada) criado em um hospital universitário com os parâmetros da injeção manual e com os valores ideais da bomba injetora. Métodos Um simulador do território aórtico foi construído, e parâmetros de injeção entre os diferentes métodos em um cenário laboratorial controlado foram analisados. O teste t de Student e o teste de Mann-Whitney foram usados para análise estatística. Três residentes de Cirurgia Vascular realizaram os testes (nove usando o novo dispositivo, e nove usando a injeção manual, totalizando 54 injeções). Resultados Houve diferença estatisticamente significativa (p < 0,05) entre os dois métodos, considerando os parâmetros: variação de pressão, pressão máxima, tempo de injeção, tempo até a pressão máxima e volume até a pressão máxima. Conclusões A manivela articulada atingiu níveis superiores de pressão e de velocidade de injeção, com menor tempo de injeção do que a injeção manual. É um dispositivo simples, de baixo custo e com resultados comparáveis à bomba injetora, o que sugere seu uso potencial na geração de imagens satisfatórias em aortografias.


Assuntos
Bombas de Infusão , Radiologia Intervencionista/instrumentação , Meios de Contraste/administração & dosagem , Procedimentos Cirúrgicos Vasculares , Angiografia/instrumentação , Tecnologia de Baixo Custo , Custos e Análise de Custo , Procedimentos Endovasculares , Injeções/instrumentação
3.
Artigo em Inglês | MEDLINE | ID: mdl-27013077

RESUMO

The total amount of scientific literature has grown rapidly in recent years. Specifically, there are several million citations in the field of cancer. This makes it difficult, if not impossible, to manually retrieve relevant information on the mechanisms that govern tumor behavior or the neoplastic process. Furthermore, cancer is a complex disease or, more accurately, a set of diseases. The heterogeneity that permeates many tumors is particularly evident in head and neck (HN) cancer, one of the most common types of cancer worldwide. In this study, we present HNdb, a free database that aims to provide a unified and comprehensive resource of information on genes and proteins involved in HN squamous cell carcinoma, covering data on genomics, transcriptomics, proteomics, literature citations and also cross-references of external databases. Different literature searches of MEDLINE abstracts were performed using specific Medical Subject Headings (MeSH terms) for oral, oropharyngeal, hypopharyngeal and laryngeal squamous cell carcinomas. A curated gene-to-publication assignment yielded a total of 1370 genes related to HN cancer. The diversity of results allowed identifying novel and mostly unexplored gene associations, revealing,for example, that processes linked to response to steroid hormone stimulus are significantly enriched in genes related to HN carcinomas. Thus, our database expands the possibilities for gene networks investigation, providing potential hypothesis to be tested. Database URL:http://www.gencapo.famerp.br/hndb.


Assuntos
Carcinoma de Células Escamosas/genética , Bases de Dados Genéticas , Bases de Dados de Proteínas , Genes Neoplásicos , Neoplasias de Cabeça e Pescoço/genética , Bandeamento Cromossômico , Redes Reguladoras de Genes , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...